Blaž Kovačič, M.Sc.
Obstino – Assistive Technology Development Association
Date
June 2026
Introduction
As a part of Obstino – Assistive Technology Development association, we’ve developed an algorithm that detects facial gestures, such as smile, eyebrow raise and mouth open. This algorithm is the subject of this article and will be presented in detail.
The algorithm is a part of our free and open source
Android app Face Control (see code on
github)
Our Face Control app (as available on the Google Play) is an assistive technology app to help disabled users control their Android devices using only movements of their face, eye gaze left/right and eye wink.
App is demonstrated below:
Our approach is written in Java code, and is outlined with the following steps: 1. Repeat-capture camera images using our CameraCapture.java class 2. Pass image to FaceDetector class from Android ML Kit’s Face Detection API to obtain the (x, y) image coordinates around special areas of the face, such as around the eyebrows – these are commonly known as facial landmarks 3. MAIN COMPONENT: Pass facial landmark points to our GestureRecognizer.java algorithms to detect changes in facial movements such as eyebrow raise and a smile
In this publication, we first explain our approach in detail for the smile detection algorithm. There we present also the necessary theoretical background and pratical considerations and put them into context of smile detection algorithm. We also present and outline the eyebrow raise detection and detection of mouth open facial gestures. Finally, we conclude by summarizing our work.
Rationale and advantages of our approach
Facial gesture detection is a very applicable area, especially in the field of assistive technology. This is so because many disabled persons, such as people with quadriplegia, only have ability to move their face/head and very limited or no ability to move the rest of their body.
The algorithm to detect, say, eyebrow raise or a smile, should be sensitive enough to detect small changes in expression – as opposed to detecting “absolute eyebrow position”. This is so because different people may have varying levels of expression of that facial gesture as compared to neutral facial expression. With this in mind, it is important to design a robust algorithm that can detect the smallest changes.
Our approach is based on designing an algorithm that receives a real time feed of facial landmark points (see image below). We must emphasise that landmark detection by itself is not sufficient for reliable face gesture detection for use in assistive technology. That’s where our algorithm does the main part of gesture detection.
Figure 1: Facial landmark points obtained through Android ML Kit Face Detection API.
In the figure above are displayed facial landmark points (or rather
contour points, to use ML Kit’s exact terminology) using our sample demo
application “ML Kit landmarks”.
Demo code available on https://github.com/obstino-org/android_facial_landmarks_demo
Some challanges that our approach addresses are outlined as follows: – difficult to detect small changes reliably – minimize false detections when user moves their head – allow to adapt detection thresholds: user should be able to choose senstivity to facial movement required to trigger facial gesture detection – detection being responsive enough during use – detect facial gestures reliably during different head tilts
Smile detection
Simplified pseudocode
// function that gets called repeatedly during camera capture
detectSmile(face) {
Lx = pixGetMouthWidth(face); // rotation independent (Pythagoras)
Lnorm = pixGetEyeWidth(face); // obtain eye width (Pythagoras)
// detect translation
Tx = pixGetNosePosX(face);
Ty = pixGetNosePosY(face);
if(firstRun) {
// pass values in function arguments to high-pass filters multiple times
// --> afterewards, filter outputs will be around 0 as expected initially
// during neutral face expression
dx = chargeHighpassFilter1(Lx);
dTx = chargeHighpassFilter2(Tx);
dTy = chargeHighpassFilter3(Ty);
} else {
// detect differences in movement
dx = highpassFilter1(Lx); // dx measures smile (mouth width change)
dTx = highpassFilter2(Tx); // how many pixels nose moved on x-plane
dTy = highpassFilter3(Ty); // how many pixels nose moved on y-plane
}
dT = sqrt(dTx^2 + dTy^2); // how many pixels nose actually moved (xy plane)
dT = dT/Lnorm; // convert from pixel units to percentages (pix/pix cancels pix units)
factor = exp(-5*dT); // high dT (==head movement) gives low factor
// final equation
Dnorm = dx/Lnorm; // normalize smile change from pixels to percentage units
Dnorm = Dnorm * factor; // low factor (close to 0) will disable smile detector
if(Dnorm >= thresh && !disableDetection) {
disableDetection = true; // disable detection while smile active
chargeLowpassFilter1(Dnorm); // init moving average filter to value Dnorm
signalize(SMILE_FOUND);
}
if(disableDetection) {
lpf = lowpassFilter1(Dnorm); // lpf measures moving average of Dnorm
if(lpf < 0.20 * thresh) // at 20% of detection threshold, enable again
disableDetection = false;
}
}Basic idea
The basic idea is that we will compute differences in mouth corner
width. High difference in mouth corner width is detected when a person
smiles, and when they stop smiling.
We use a high-pass filter to
detect such changes.
Additionally, unwanted mouth corner width change is also detected
when the head is moved. This is due to the fact that from
camera’s perspective, the pixel mouth width is not the same when head is
rotated 0° as compared to, say, 30°.
To tackle the challenge of
unwanted head movement triggering false positive detection of a smile,
we decided to implement an approach which disables smile detection
whenever head movement is detected. We do this by tracking nose
movement.
We also use a moving average filter to help us reliably detect when
user stopped the smile facial gesture, allowing us to reenable smile
detection (variable disableDetection).
Commenting particular steps in the smile detection pseudocode
Normalization step
As we can see in the pseudocode, when computing head movement
change dT, there is a normalization step
dT = dT/Lnorm. This is very important because we
need to set constant thresholds. For example, it is not meaningful
information if we know dT was, say, 20 pixels. This is so because, if
the person is further away from the camera, same head movement might
result in dT = 10 pixels. For this reason, we normalize values such as
dT and dx (the latter becomes Dnorm).
Normalization works because
dividing pixels by pixels cancels out pixel units, leading to percentage
(or ratio) units. The meaning of normalized dT in our case is then “what
percentage of eye width did the point move?”
Where is dT used and why
In code, we use dT to compute factor in such a manner
that factor is low (close to 0) whenever head movement change dT is a
high value, and high (close to 1) whenever dT is a low value. This means
that when we multiply Dnorm = Dnorm * factor, when head
movement is high, Dnorm will be close to zero. This is desired
behaviour, because it prevents false positive detections of a smile when
head position changes.
We achieve this using an empirically designed
exponential decay equation: \(\text{factor}(dT) = e^{-5\times dT}\).
This equation is convenient, because at \(\text{factor}(dT = 0) = 1\). The value
\(-5\) in the exponential decay
equation was determined empirically. We can see that evaluating \(\text{factor}(dT = 0.3) = 0.22\) results in
quite high attentuation when head (or rather nose) is moved 30% (0.3) of
eyewidth distance. If we wanted higher attenuation, we can just set an
even more negative value than \(-5\) in
the equation.
Detecting changes using high-pass filters
Background
As mentioned, our approach is based on detecting small differences in
movement of facial landmark points. In our case, we want to help
disabled user control their device using the facial gesture of a smile.
For this to work, the algorithm should be tuned in a way that is able to
detect both sudden changes in mouth corner width as well as slower.
Mouth corner width is essentially just a number that we compute (pixels
units). Because different people have different mouth width, and because
mouth width depends on distance from camera, the number itself will not
yield useful information. Therefore, we must be able to track
changes in that number.
There are different ways to approach detecting such a change, but all
ways essentially boil down the the same principle: a high-pass filter.
Indeed, even if(width[t] - width[t-1] > threshold) is a
high-pass filter (1-tap FIR difference filter). It is however
not the best one for our use case, as it wouldn’t respond to a slow
smile, and it could even overly respond to sudden changes, resulting in
multiple detections.
For this purpose we decided to programmatically implement an IIR
(infinite impulse response) filter based on 1st order passive
CR filter electronic circuit, which is a high-pass filter variant of
the exponential
smoothing filter.
Some benefits of using an CR filter are the following: – compared to FIR filters, in this design we didn’t need to know in advance the exact sampling frequency of the filter – sampling frequency in our case is the dynamically changing Frames Per Second of the camera image feed (depends on device and CPU load that happens when computing facial landmarks); it means how many times per second we provide mouth corner width into the filter – we can dynamically update sampling frequency – compared to FIR filters with fixed set of coefficients, we can here instead easily programmatically change the cutoff frequency – cutoff frequency in high-pass filters means how much the filter will respond to slower changes in input signal (mouth corner width in our case) – because slow changes have a high time duration, they have low frequency – setting a low cutoff frequency will allow those slower, low frequency signals, to pass through, whereas a high cutoff frequency will respond to fast changes only – we can empircally determine the optimal cutoff frequency – CR filter is a well known circuit – only 1 parameter determines the filter, namely the cutoff frequency (not counting sampling frequency) – cutoff frequency is directly related to the time it takes the filter to adapt to changes
Example high-pass filter output
We will now demonstrate how the high-pass filter works when detecting
a smile using mouth corner width Lx.

Figure 2: High-pass filter output (dx) with input mouth corner width signal (Lx) during smile facial gesture.
In the image above, we assumed sample frequency 30 Hz, which is
due to typical 30 frame per second camera image feed update.
For first second (30 frames on horizontal time axis) the user’s mouth
corner width corresponded to a neutral expression. However, after 1
second, during a smile, mouth corner width Lx increased to
20 pixels, and went back down to 13 pixels. We can notice it didn’t go
back down to 10 pixels, which is understandable because of dynamic
nature of facial expressions.
You can see that after the smile gesture, the green signal needed some time to fall back towards zero, i.e. it needed time to adapt to a new input constant baseline value (value of 13 [pix] in this case). Later we will discuss how to make our high-pass filter adapt to this new input constant baseline faster or slower, though a variable called cutoff frequency – inversely related to the fall time which will also be discussed.
Now the important thing we achieved here using a high-pass filter is
the ability to detect change in mouth corner width. High-pass
filter output is shown as a the green signal in the image. As we can
see, the filter output dx followed signal Lx,
and after the change it slowly returned back to 0 pixels on vertical
axis.
This is very desirable, because it allows us to specify a
fixed threshold value used to detect a facial gesture (smile in this
case). Threshold can be used because the filter output dx
is centered around zero, as opposed to the signal Lx whose
baseline value can vary.
As we can see in the figure above, the output from high-pass filter approaches value 0 after smile gesture has finished. If the filter cutoff frequency was set to a higher value, there might be less response (smaller peak) to slower mouth corner width changes, but it would approach 0 faster.
Theoretical background on high-pass CR filter
CR filter is a simple electronic circuit which is designed to allow fast (high-frequency) signals to pass through, and attenuate slow (constant or low-frequency) signals. It is named CR because it consisits of a capacitor (C for capacitance, as measured in farad units) and a resistor (R for resistance, as measured in ohm units).
As we know, electronic circuits can be simulated on computers, and this is done by solving differential equations through numerical methods.
CR circuit also has a differential equation that we can use to simulate its behaviour (i.e. changing input and output voltages) on a computer. Without going into too much details, this be obtained through CR filter’s Laplace transfer function, and the differential equation is as follows: \[v_{out}(t) + RC\cdot v_{out}'(t) = RC\cdot v_{in}'(t)\]
We can substitute \(v_{out}(t) =
y[n]\) (output signal), \(v_{in}(t) =
x[n]\) (input signal), and obtain the ‘backward differences’ for
derivates as \(v_{out}'(t) = \frac{y[n] –
y[n-1]}{T_{s}}\) and \(v_{in}'(t) =
\frac{x[n] – x[n-1]}{T_{s}}\). Here \(T_s\) is the sampling period that has
corresponding sampling frequency \(f_s = 1 /
T_s\), which in our case is equal to the frame rate (about 30
frames per second).
The differential equation then becomes the
following difference equation: \[y[n] +
RC\left[\frac{y[n] – y[n-1]}{T_s}\right] = RC\left[\frac{x[n] –
x[n-1]}{T_s}\right]\] It is also known that for CR filter
circuit, the product \(R\cdot C\) is
equal to so-called time constant \(\tau =
RC\). Expressing this difference equation in terms of \(\tau\) and \(f_s\), we obtain: \[y[n] = \alpha\big(x[n] – x[n-1] + y[n-1]
\big)\] where \[\alpha = \frac{\tau
f_s}{1 + \tau f_s}\]
We can readily use the obtained difference equation for \(y[n]\) to compute the filter output at sample \(n\), knowing only input signal values and present and previous time point and filter output at previous time point.
CR filter also has a so-called ‘cutoff frequency’ \(f_c\), which is a frequency below which
signals are more and more attenuated. There holds the relation \(f_c = \dfrac{1}{2\pi \tau}\) which yields
\(\alpha = \dfrac{f_s}{f_s + 2\pi
f_c}\).
Since the sampling frequency \(f_s\) is known during image capture code to be up to 30 Hz (camera frame rate, FPS), the only question remains is how to set the cutoff frequency \(f_c\).
For example, suppose \(f_c =
0.1~\text{Hz}\) and \(f_s =
30~\text{Hz}\), as is the case for our smile detection algorithm.
From the \(y[n]\) difference equation
above, it can be determined that if \(x[n]=1\), \(x[n-1]=0\) and \(y[n-1]=0\), then \(y[n] = \alpha = \frac{30}{30 + 2\pi\cdot 0.1}
\approx 0.98\). Clearly, the high-pass output for a fast changing
input signal (from 0 to 1 in this case) will directly follow the input
signal, in this case it will immediately reach 98% of the input
value.
Such is the case when cutoff frequency is much lower than the
sampling frequency.
One can determine the \(f_c\) empirically, or by a heuristic such
as the desired fall time of the filter. The latter can be
computed using CR filter’s unit step response, which is an exponentially
decaying function. Fall time, i.e. time it takes the filter to go from
90% to 10% of peak value, can be shown to be equal to \(t_f = \dfrac{2.197}{2\pi f_c}\) or
equivalently \(f_c = \dfrac{2.197}{2\pi
t_f}\).
If, for example, one then desires 3 seconds for the
value to adapt to the new constant baseline, one then sets \(t_f = 3 ~\text{sec}\), obtaining \(f_c = 0.11~\text{Hz}\), as is the case in
our code.
In our code, we used multiple high-pass fiters, for example one was
used for dx computation, another for dTx and
dTy. In these filters, we set different cutoff frequency
values.
The filter can be implemented in Java as follows:
class HighpassFilter {
private double f_sampling;
private double f_cutoff;
private double prev_x = 0;
private double prev_y = 0;
HighpassFilter(double f_sampling, double f_cutoff) {
this.f_sampling = f_sampling;
this.f_cutoff = f_cutoff;
prev_x = 0;
prev_y = 0;
}
void setSamplingFrequency(double f_sampling) {
this.f_sampling = f_sampling;
}
void setCutoffFrequency(double f_cutoff) {
this.f_cutoff = f_cutoff;
}
double computeSample(double x) {
double alpha;
double y;
alpha = (double)f_sampling/(2*PI*f_cutoff + (double)f_sampling);
y = alpha*prev_y + alpha*(x - prev_x);
prev_y = y;
prev_x = x;
return y;
}
double chargeSample(double x) {
// It takes 5*Tau seconds to 'charge' a RC filter; Tau=1/(2*PI*fc) [sec] and 5 sec = 5*fs samples
double ret = 0;
for (int k = 0; k < (int)(5.0*f_sampling / (2.0*PI*f_cutoff)); k++)
ret = computeSample(x);
return ret;
}
}We can see that in the code above, there is also a function called
chargeSample. This function is used during the first run of
smile detection algorithm (chargeHighPassFilter function in
pseudocode). As stated in the pseudocode, this function will pass value
from the input argument to a high-pass filters multiple times, after
which the filter output will be around 0 as expected initially during
neutral face expression. If we didn’t charge the filters on first
execution of the algorithm, initially a false positive detection might
be triggered. This is so, because a newly initialized filter assumes all
past inputs to have been zero, and the filter gets triggered by a
neutral face expression (say, 20 pixels) just the same as it would if a
smile gesture was present (say, 25 pixels). After charging, however, the
filter output is zero for neutral face expression, and positive for a
smile gesture (e.g. giving 25 – 20 pixels = 5 pixels at filter
output).
Using a low-pass filter to detect end of gesture
Background
We use a low-pass RC filter, also known as exponential moving average filter, in our algorithm. We apply the filter after the smile gesture has been detected in order to reliably detect the end of smile gesture.
As we can see in the smile detection pseudocode, when the smile has
been detected (Dnorm >= thresh), we ‘charge’ this
low-pass RC filter using chargeLowpassFilter1(Dnorm);. This
function basically passes value Dnorm (normalized mouth
corner width difference) through the filter multiple times. This sets
the filter output value approximately to Dnorm the next
time lowpassFilter1 function is called.
After the smile detection onset, we need to then detect the end of
gesture. We do this by passing new values of Dnorm through
the algorithm during each algorithm execution. When low-pass filter
output falls below 20% of detection threshold, we can safely say that
the gesture has been completed. This is important, because otherwise
noise or other facial movement might falsely trigger multiple
detections, which is why the low-pass filter plays an important role
here.

Figure 3: Low-pass filter output (lpf) with input mouth corner width signal (Lx) during smile facial gesture.
As we can see in the figure above, after detection of smile
gesture, lowpass filter (blue signal in figure) was charged to value
around 8, and slowly followed smile difference value dx (dotted green
signal in figure). Slow adaptation to differences in dx using the
low-pass filter is appropriate, because during our accessibility
application of smile gesture detection, we often detect very small
changes, smaller than those in the example figure above. This improves
robustness to multiple/false detections, and the rate of how fast/slow
the low-pass filter adapts can be varied using different filter cutoff
frequencies. More about implementing the RC filter and setting the
cutoff frequency will be presented in the following subsection.
Theoretical background on low-pass RC filter
From the Laplace transform equation of the low-pass RC filter, the following differential equation can be obtained:
\[v_{out}(t) + RC v_{out}'(t) = v_{in}(t)\]
Similarily as we did for the high-pass filter, we substitute \(v_{out}(t) = y[n]\) (output signal), \(v_{in}(t) = x[n]\) (input signal), and \(v_{out}'(t) = \frac{y[n] – y[n-1]}{T_{s}}\) (\(T_s\) being the sampling period, inverse of sampling frequency \(f_s\)).
Substituting and rearranging we obtain: \[y[n] = \alpha x[n] + (1 – \alpha)x[n-1]\] where \[\alpha = \frac{1}{1 + \tau f_s} = \frac{2\pi f_c}{f_s + 2\pi f_c}\]
Here we substituted \(\tau = RC = \dfrac{1}{2\pi f_c}\) where \(\tau\) is a time constant and \(f_c\) is RC filter’s cutoff frequency.
If \(f_c\) is a low value, putting a
rapidly changing (high-frequency) signal through the RC filter will
produce attenuated or zero output at the filter. On the other hand,
putting a slowly changing (low-frequency or constant) signal through the
filter will preserve only low-frequency components of the signal at the
filter output.
Just as for the high-pass filter, the time (fall-time \(t_f\)) it takes the low-pass RC filter to
discharge from 90% to 10% of its initial value, can be shown to be equal
to \(t_f = \dfrac{2.197}{2\pi f_c}\) or
equivalently \(f_c = \dfrac{2.197}{2\pi
t_f}\).
If we know desired fall time, the equation above
allows us to determine the cutoff frequency for our filter.
For
example, suppose that initially filter output \(y[0] = 10\) and we set \(x[n\gt0]=0\). Now we want to know what
cutoff frequency \(f_c\) to use in
order for filter output \(y\) to adapt
to new value \(0\). If we want this to
happen in 1 second, we can simply compute \(f_c = \frac{2.197}{2\pi\times 1} \approx 0.35
Hz\). This then is the frequency we would set in code.
What follows is low-pass RC filter implementation in Java:
class LowpassFilter {
private double f_sampling; // sampling frequency
private double f_cutoff;
private double prev_y = 0;
LowpassFilter(double f_sampling, double f_cutoff) {
this.f_sampling = f_sampling;
this.f_cutoff = f_cutoff;
prev_y = 0;
}
void setSamplingFrequency(double f_sampling) {
this.f_sampling = f_sampling;
}
void setCutoffFrequency(double f_cutoff) {
this.f_cutoff = f_cutoff;
}
double computeSample(double x) {
double alpha;
double y;
alpha = 2*PI*f_cutoff / (2*PI*f_cutoff + f_sampling);
y = alpha*x + (1 - alpha)*prev_y;
prev_y = y;
return y;
}
double chargeSample(double x) {
// It takes 5*Tau seconds to 'charge' a RC filter; Tau=1/(2*PI*fc) [sec] and 5 sec = 5*fs samples
double ret = 0;
for (int k = 0; k < (int)(5.0*f_sampling / (2.0*PI*f_cutoff)); k++)
ret = computeSample(x);
return ret;
}
}Mouth open detection
Simplified pseudocode
// function that gets called repeatedly during camera capture
detectMouthOpen(face) {
Lx = pixGetMouthWidth(face); // rotation independent (Pythagoras) -- distance between mouth corners
Ly = pixGetMouthHeight(face); // rotation independent (Pythagoras) -- distance between upper and lower mid lip
Lnorm = pixGetEyeWidth(face); // (Pythagoras)
// detect translation
Tx = pixGetNosePosX(face);
Ty = pixGetNosePosY(face);
mouthRatio = Ly/Lx;
if(firstRun) {
// pass values in function arguments to filters multiple times
// --> afterewards, high-pass filter outputs will be around 0 as expected initially, and low-pass filter output will be equal to Ly
fy = chargeLowpassFilter1(Ly);
dTx = chargeHighpassFilter1(Tx);
dTy = chargeHighpassFilter2(Ty);
} else {
// detect differences in movement
fy = lowpassFilter1(Ly); // fy measures mouth open (mouth height)
dTx = highpassFilter1(Tx); // how many pixels nose moved on x-plane
dTy = highpassFilter2(Ty); // how many pixels nose moved on y-plane
}
dT = sqrt(dTx^2 + dTy^2); // how many pixels nose actually moved (xy plane)
dT = dT/Lnorm; // convert from pixel units to percentages (pix/pix cancels pix units)
factor = exp(-5*dT); // high dT (==head movement) gives low factor
// final equation
Dnorm = fy/Lnorm; // normalize mouth open distance from pixels to percentage units
Dnorm = Dnorm * factor; // low factor (close to 0) will disable mouth open detector
if(Dnorm >= thresh && mouthRatio >= 0.25 && !disableDetection) {
disableDetection = true; // disable detection while mouth open active
signalize(MOUTH_OPEN);
}
if(disableDetection) {
if(Dnorm < 0.40 * thresh) // at 40% of detection threshold, enable again
disableDetection = false;
}
}Comment
The principle of functioning is similar as with smile detection.
First difference here is that we use a low-pass filter as a primary tool
to detect mouth open. Similar as with smile detection, we normalize
mouth open from pixel units to percentage units (or ratios) by dividing
mouth open distance by eye width in pixels. This done by the line
Dnorm = fy/Lnorm, where fy is the moving average of mouth
open distance and Lnorm is eye width in pixels. This effectively gives
us Dnorm, which gives the mouth open distance as a
percentage of eye width.
Another difference as compared to smile detection code is that here
two triggers have to happen in order for the code to reliably register
detection. The first is Dnorm >= thresh, and another is
given as mouthRatio >= 0.25.
Here
mouthRatio is the ratio between mouth open height and mouth
corner width.
Other than the two named differences, the principle of false positive
detection prevention code is based the same way as in smile detection
code, namely by attenuating mouth open distance Dnorm when
head movement is detected (Dnorm = Dnorm * factor in the
code above).
Detecting eyebrow raise
Simplified pseudocode
// function that gets called repeatedly during camera capture
detectEyebrowRaise(face) {
Lnorm = pixEyeWidth(face); // rotation independent (Pythagoras)
// compute angle (alpha = asin(y/D)) -- see figure 5
angle = arcsin(eyeCornerHeightDiff / eyeCornerDistance) // compute head side tilt (roll angle)
Ly = pixNoseToEyebrowDistance(face, angle); // note that eyebrow position is average of 4 eyebrow landmark points (Ly is rotation independent)
// detect translation
Tx = pixGetNosePosX(face);
Ty = pixGetNosePosY(face);
if(firstRun) {
// pass values in function arguments to high-pass filters multiple times
// --> afterewards, filter outputs will be around 0 as expected initially
// during neutral face expression
dy = chargeHighpassFilter1(Ly);
dTx = chargeHighpassFilter2(Tx);
dTy = chargeHighpassFilter3(Ty);
} else {
// detect differences in movement
dy = highpassFilter1(Ly); // dy measures eyebrow raise (nose to eyebrow distance change)
dTx = highpassFilter2(Tx); // how many pixels nose moved on x-plane
dTy = highpassFilter3(Ty); // how many pixels nose moved on y-plane
}
dT = sqrt(dTx^2 + dTy^2); // how many pixels nose actually moved (xy plane)
dT = dT/Lnorm; // convert from pixel units to percentages (pix/pix cancels pix units)
factor = exp(-5*dT); // high dT (==head movement) gives low factor
// final equation
Dnorm = dy/Lnorm; // normalize eyebrow change from pixels to percentage units
Dnorm = Dnorm * factor; // low factor (close to 0) will disable eyebrow raise detector
if(Dnorm >= thresh && !disableDetection) {
disableDetection = true; // disable detection while eyebrow raise active
chargeLowpassFilter1(Dnorm); // init moving average filter to value Dnorm
signalize(EYEBROW_RAISE_FOUND);
}
if(disableDetection) {
lpf = lowpassFilter1(Dnorm); // lpf measures moving average of Dnorm
if(lpf < 0.20 * thresh) // at 20% of detection threshold, enable again
disableDetection = false;
}
}Comment
The code is most similar to smile detection in the following way: – a highpass filter is used to detect a change in eyebrow height level – a lowpass filter is used to detect the end of eyebrow raise gesture – highpass filters are used to detect head movement, disabling detection when such movement is present
The distance Ly from pseudocode is illustrated in the
Figure 4 below.

Figure 4: Demonstration of distance Ly in eyebrow raise detection code. The 4 green points on eyebrow and 1 green point on nose illustrate a selected subset of landmark points used to detect eyebrow raise.

Figure 5: Demonstration of head side tilt computation using landmark points (green) on the outer corners of the eyes. Here α corresponds to ‘angle’ in pseudocode, whereas y and D correspond to ‘eyeCornerHeightDiff’ and ‘eyeCornerDistance’ in pseudocode.
The most important things about eyebrow raise detection code are the following:
- The algorithm doesn’t measure only eyebrow position
differences.
We don’t merely measure when positions of eyebrow pixels changes, because this would give false detections when head is moved. Instead we measure differences in distance between nose position and between eyebrow position (distance Ly in Figure 4). Additionally that distance is normalized with respect to eye width in pixels, making the algorithm robust to head movement towards and away from the camera. - We make sure the algorithm works even when head is tilted (side tilts left/right, i.e. roll angle). This is important because some users’ neutral head positions during usage may vary (for example due to their condition). We compute head angle using trigonometric functions, using points around eyes as input to this calculations (see Figure 5).
- Eyebrow position is computed by using the average of 4 green points on left eyebrow (Figure 4), for most reliable detection.
Conclusion
In this article we introduced our accessibility Android application Face Control, and described in detail the algorithms we implemented and the mathematical background that enable it to achieve robust detection of facial gestures. The gestures described are detection of smile, mouth open and eyebrow raise.
The advantage of our approach is that it doesn’t require many parameters in order for it to work. Instead the approach is robust under different frame rates of camera capture, and is ready to use without complex setup. Even so, if users desire higher sensitivity to facial gesture detection, the approach allows for easy programmatical adjustability of the parameters, as is the case in our implementation of Face Control.
In the article for most part the gesture detection code is written in pseudocode, however the reader is invented to view the full Face Control app Java source code, available freely on GitHub (https://github.com/obstino-org/facecontrol).